EX-Equipment > Catalogs

Catalogs

Name Manufacturer Description
YC11Y-JZ PUR , 12G0,75  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 18G0,75  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 25G0,75  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 2x1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 3G1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 4G1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 5G1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 7G1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 12G1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 18G1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 25G1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 2x1,5  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 3G1,5  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 4G1,5  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 5G1,5  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 7G1,5  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 15G1,5  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 18G1,5  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 25G1,5  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 3G2,5  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 4G2,5  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 5G2,5  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
YC11Y-JZ PUR , 4G4,4  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -40° C to +70° CRated voltage: 300/500 V, Test voltage: 3000 V, Bending radius: 20 x cable diameter, PUR control cable
H05/H07 BQ-F , 2x0,75  SCANFLEX  Working temperature: -40° C to +80° C, Rated voltage: 450/750 V, Test voltage: 3000 V, Bending radius: 12,5 x cable diameter, Technical comments: Insulations resistance:10 MOhm/km PUR control cable
H05/H07 BQ-F , 3G0,75  SCANFLEX  Working temperature: -40° C to +80° C, Rated voltage: 450/750 V, Test voltage: 3000 V, Bending radius: 12,5 x cable diameter, Technical comments: Insulations resistance:10 MOhm/km PUR control cable
H05/H07 BQ-F , 4G0,75  SCANFLEX  Working temperature: -40° C to +80° C, Rated voltage: 450/750 V, Test voltage: 3000 V, Bending radius: 12,5 x cable diameter, Technical comments: Insulations resistance:10 MOhm/km PUR control cable
H05/H07 BQ-F , 5G0,75  SCANFLEX  Working temperature: -40° C to +80° C, Rated voltage: 450/750 V, Test voltage: 3000 V, Bending radius: 12,5 x cable diameter, Technical comments: Insulations resistance:10 MOhm/km PUR control cable
H05/H07 BQ-F , 2x1  SCANFLEX  Working temperature: -40° C to +80° C, Rated voltage: 450/750 V, Test voltage: 3000 V, Bending radius: 12,5 x cable diameter, Technical comments: Insulations resistance:10 MOhm/km PUR control cable
H05/H07 BQ-F , 3G1  SCANFLEX  Working temperature: -40° C to +80° C, Rated voltage: 450/750 V, Test voltage: 3000 V, Bending radius: 12,5 x cable diameter, Technical comments: Insulations resistance:10 MOhm/km PUR control cable
H05/H07 BQ-F , 4G1  SCANFLEX  Working temperature: -40° C to +80° C, Rated voltage: 450/750 V, Test voltage: 3000 V, Bending radius: 12,5 x cable diameter, Technical comments: Insulations resistance:10 MOhm/km PUR control cable
H05/H07 BQ-F , 5G1  SCANFLEX  Working temperature: -40° C to +80° C, Rated voltage: 450/750 V, Test voltage: 3000 V, Bending radius: 12,5 x cable diameter, Technical comments: Insulations resistance:10 MOhm/km PUR control cable
H05/H07 BQ-F , 2x1,5  SCANFLEX  Working temperature: -40° C to +80° C, Rated voltage: 450/750 V, Test voltage: 3000 V, Bending radius: 12,5 x cable diameter, Technical comments: Insulations resistance:10 MOhm/km PUR control cable
H05/H07 BQ-F , 3G1,5  SCANFLEX  Working temperature: -40° C to +80° C, Rated voltage: 450/750 V, Test voltage: 3000 V, Bending radius: 12,5 x cable diameter, Technical comments: Insulations resistance:10 MOhm/km PUR control cable
H05/H07 BQ-F , 4G1,5  SCANFLEX  Working temperature: -40° C to +80° C, Rated voltage: 450/750 V, Test voltage: 3000 V, Bending radius: 12,5 x cable diameter, Technical comments: Insulations resistance:10 MOhm/km PUR control cable
H05/H07 BQ-F , 5G1,5  SCANFLEX  Working temperature: -40° C to +80° C, Rated voltage: 450/750 V, Test voltage: 3000 V, Bending radius: 12,5 x cable diameter, Technical comments: Insulations resistance:10 MOhm/km PUR control cable
H05/H07 BQ-F , 4G2,5  SCANFLEX  Working temperature: -40° C to +80° C, Rated voltage: 450/750 V, Test voltage: 3000 V, Bending radius: 12,5 x cable diameter, Technical comments: Insulations resistance:10 MOhm/km PUR control cable
YSLY/EB-JZ / YSLY/EB-OZ , 2x0,75  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -30° C to +70° CRated voltage: 300/500 V, Test voltage: 2000 V, Bending radius: 15 x cable diameterBlue control cables for intrinsically safe circuits
YSLY/EB-JZ / YSLY/EB-OZ , 3x0,75  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -30° C to +70° CRated voltage: 300/500 V, Test voltage: 2000 V, Bending radius: 15 x cable diameterBlue control cables for intrinsically safe circuits
YSLY/EB-JZ / YSLY/EB-OZ , 5G0,75  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -30° C to +70° CRated voltage: 300/500 V, Test voltage: 2000 V, Bending radius: 15 x cable diameterBlue control cables for intrinsically safe circuits
YSLY/EB-JZ / YSLY/EB-OZ , 7G0,75  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -30° C to +70° CRated voltage: 300/500 V, Test voltage: 2000 V, Bending radius: 15 x cable diameterBlue control cables for intrinsically safe circuits
YSLY/EB-JZ / YSLY/EB-OZ , 25G0,75  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -30° C to +70° CRated voltage: 300/500 V, Test voltage: 2000 V, Bending radius: 15 x cable diameterBlue control cables for intrinsically safe circuits
YSLY/EB-JZ / YSLY/EB-OZ , 2x1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -30° C to +70° CRated voltage: 300/500 V, Test voltage: 2000 V, Bending radius: 15 x cable diameterBlue control cables for intrinsically safe circuits
YSLY/EB-JZ / YSLY/EB-OZ , 3x1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -30° C to +70° CRated voltage: 300/500 V, Test voltage: 2000 V, Bending radius: 15 x cable diameterBlue control cables for intrinsically safe circuits
YSLY/EB-JZ / YSLY/EB-OZ , 5G1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -30° C to +70° CRated voltage: 300/500 V, Test voltage: 2000 V, Bending radius: 15 x cable diameterBlue control cables for intrinsically safe circuits
YSLY/EB-JZ / YSLY/EB-OZ , 7G1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -30° C to +70° CRated voltage: 300/500 V, Test voltage: 2000 V, Bending radius: 15 x cable diameterBlue control cables for intrinsically safe circuits
YSLY/EB-JZ / YSLY/EB-OZ , 12G1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -30° C to +70° CRated voltage: 300/500 V, Test voltage: 2000 V, Bending radius: 15 x cable diameterBlue control cables for intrinsically safe circuits
YSLY/EB-JZ / YSLY/EB-OZ , 18G1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -30° C to +70° CRated voltage: 300/500 V, Test voltage: 2000 V, Bending radius: 15 x cable diameterBlue control cables for intrinsically safe circuits
YSLY/EB-JZ / YSLY/EB-OZ , 25G1,0  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -30° C to +70° CRated voltage: 300/500 V, Test voltage: 2000 V, Bending radius: 15 x cable diameterBlue control cables for intrinsically safe circuits
YSLY/EB-JZ / YSLY/EB-OZ , 3G1,5  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -30° C to +70° CRated voltage: 300/500 V, Test voltage: 2000 V, Bending radius: 15 x cable diameterBlue control cables for intrinsically safe circuits
YSLY/EB-JZ / YSLY/EB-OZ , 4G1,5  SCANFLEX  Working temperature: Flexible:-5° C to +70° CFixed: -30° C to +70° CRated voltage: 300/500 V, Test voltage: 2000 V, Bending radius: 15 x cable diameterBlue control cables for intrinsically safe circuits
Page: 12345678910

Термореле 26QL,QM 01-017021-300 (-73,3 до +148С)
Пневмоусилитель Midland Pneumatic 2325M21-EC2B 1/4” NPT 3/2 MAX WP-12BAR

Датчик температуры THERMO EST SI/14 type SI 14.1 EExd

Трансмитер AGM DIN4000-13F
Датчик вибрации Bently Nevada 30008-00-12-30-02
Кабель датчика Bently Nevada 2789-180